AIR-ELECTRIC CONVERTERS for COMPUTER GAGE STATIONS
Model AEK II Air-Electric converters coupled with GageChek Readouts or PC Computer Gage Stations provide more computing capacity than Micro II readouts. These converters use the same proven air gage interface modules as the Micro II and Millicheck Readouts, each converter unit accommodates up to four analog and serial digital outputs in one shop hard housing. Multiple AEK converters can be stacked to accommodate complex applications.
AEK II Air-electric converter technical data
Gage inputs:
Specify from 1 to 4 Air gage or LVDT modules per enclosure. (Modules are the same as for Micro II readouts).
Analog outputs:
Up to four, ±10 VDC full scale outputs, ( 1.0 ma. max.) on 9 pin Sub-D female connector.
Digital output:
Serial RS-232C, continuously
outputs the analog voltage values for each
channel, ten one word updates per second.
Uses: Carriage return and line feed delimiters,
Data bits: 8, Baud rate: 9600.
(9 pin Sub-D male connector).
Controls, front panel:
Channel select
Zero adjust
Span adjust (dual master only)
Pneumatic Zero adjust (A/G modules only)
Controls, rear panel:
Channel gain adjust lockouts
Zero adjust lockout (global)
Serial output rate
Air gage module requirements:
.5 to 2 SCFM @ 40 to 125 psi (The actual air flow
depends on nozzle sizes and gaging ranges of the
air gage members connected to the readout).
Power:
User supplied: 9 - 30 VDC, 300 ma. when used with 4 air
modules (600 ma. with 4 LVDT modules); requires 5.5/2.1
mm female plug (Digkey/CUI Inc #PP-002A or equivalent).
Or use WGC power supplies:
PSR-30, 110-120 VAC 60 Hz (USA)
PSR-31 Universal Power supply 100-240 VAC 50-60 Hz
(Includes plug adapters for North America, Australia,
U.K., Europe).
Weight: 7 Lbs (3.2 Kg)